<LOGO>
FM Transmitter Measurement Report
Created: 2025-02-06 14-03-50
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
105.90 MHz 5/5, 45 dBuV RTL2
Pilot RDS Phase Difference
6.8 kHz 4.1 kHz 0 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
29 kHz 82 kHz 8125 91,3108
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,0 dBr
MIN AVE MAX % above 10,0 dBr
8,2 dBr 8,61 dBr 9,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" RTL2 " F215 0 (No PTY) 1 0 1 2 14:03, 6.02.2025
RT
"RTL2, Le Son POP-ROCK "
AF EON
88.2, 89.1, 89.2, 90.1, 92.2, 92.4, 94.4, 95.9, 96.6, 97.3, 97.4, 98.0, 98.2, 98.3, 98.9, 99.3, 101.3, 103.2, 105.1, 105.3, 105.9, 106.0, 106.1, 106.9 MHz -
FM Scope Station: 105.90 MHz, signal: 4/5 (47 dBuV) Max at: 82 kHz MIN: 29 kHz % above 75 kHz: 91,3108 Acquired: 2025/02/06 14:02:46 Total samples: 8125 Equivalent time: 0:06:46 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500
FM Scope MAX: 9,2 dBr MIN: 8,2 dBr AVE: 8,61 dBr % above 10,0 dBr: 0,0 Last value: 9,2 dBr (2025/02/06 14:02:46) Station: 105.90 MHz, signal: 4/5 (48 dBuV) 13:56 13:57 13:58 13:59 14:00 14:01 14:02 0 50 100 Dev. MAX [kHz] 0 5 10 Pm [dBr] 0 5 Signal Quality